Last edited by Shazahn
Thursday, July 30, 2020 | History

1 edition of Implementation of an IBM-PC/AT as a GPIB controller found in the catalog.

Implementation of an IBM-PC/AT as a GPIB controller

George H Jr Self

Implementation of an IBM-PC/AT as a GPIB controller

by George H Jr Self

  • 59 Want to read
  • 35 Currently reading

Published .
Written in English

    Subjects:
  • Electrical and computer engineering

  • The Physical Object
    Pagination79 p.
    Number of Pages79
    ID Numbers
    Open LibraryOL25461626M

    GPIB. If V% is zero, no shadow handshake or holdoff is done. The IBGTS function causes the GPIB-PC to go to the Controller Standby state and to unassert the ATN signal if it initially is the Active Controller. IBGTS permits GPIB devices to transfer data without the GPIB-PC being a party to the transfer. The IBM General Purpose Interface Bus (GPIB) Adapter connects IBM Personal Computer products (PC) to a general-purpose interface bus (bus) and is designed according to the specifications of the following industry standards as understood and interpreted by IBM as of September ANSI/IEEE Std. (includes supplement IEEE Std. A).

    GPIB controllers send commands to all of the devices in the GPIB network and convert active talkers to active listeners as necessary. A minimum system consists of one GPIB controller and one talker or listener; however, the current GPIB standard allows up to 14 devices to be connected to a GPIB . Ugplus USB to GPIB Controller Made in USA. $ New. National Instruments C PCMCIA-GPIB IEEE Card w Cable & Software. 5 out of 5 stars (1) Total Ratings 1, $ New. $ Used. National Instruments Ni Pci-gpib Interface Adapter Card f RoHS. $ New. $ Used.

      The NI driver can currently support up to GPIB controllers. This includes those connected by PCI, PXI, USB, and others. In most systems, the maximum number of GPIB-USB controllers is limited by the power supply of the associated USB port. The maximum specified current draw of the GPIB-USB-B is mA and mA for the GPIB-USB-HS. Connect a power cord to each instrument, and then connect each instrument to the computer serving as the GPIB controller. Power up all the instruments on the GPIB bus. Check each GPIB instrument for proper communication over the bus and the required "detectable" options. Follow the process described in "Checking GPIB Bus Devices" below.


Share this book
You might also like
Tell Me about World Heritage (Discovering the World)

Tell Me about World Heritage (Discovering the World)

Common heritage or common burden?

Common heritage or common burden?

International Economic Indicators

International Economic Indicators

Preliminary report on the Te Arawa representative geothermal resource claims (Wai 153)

Preliminary report on the Te Arawa representative geothermal resource claims (Wai 153)

Tappings!

Tappings!

Technical education

Technical education

Globalization and the Poor

Globalization and the Poor

Lewis and Clark Expedition

Lewis and Clark Expedition

Phonics We Use 3

Phonics We Use 3

Touching marble

Touching marble

role of strategic alliances in emerging markets.

role of strategic alliances in emerging markets.

exiled heart

exiled heart

Virtual Optical Bench

Virtual Optical Bench

Cancer of the breast and its surgical treatment.

Cancer of the breast and its surgical treatment.

It stands to reason

It stands to reason

Guide to limited liability companies

Guide to limited liability companies

Implementation of an IBM-PC/AT as a GPIB controller by George H Jr Self Download PDF EPUB FB2

Full text of "Implementation of an IBM-PC/AT as a GPIB other formats DUDLEY KNOX LIBRARY NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA NAVAL POSTGRADUATE SCHOOL Monterey, California THESIS IMPLEMENTATION OF AN IBM-PC/AT AS A GPIB CONTROLLER by George H.

Self, Jr. December Thesis Advisor: Prof. Powers. Implementation of an IBM-PC/AT as a GPIB Controller by George H. Self, Jr. Lieutenant, United States Coast Guard B.S., U.S.

Coast Guard Academy, Submitted in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE IN ELECTRICAL ENGINEERING from the NAVAL POSTGRADUATE SCHOOL December Author: / Georg- H.

Self, ir. Implementation of an IBM-PC/AT as a GPIB controller. By George H. Self Download PDF (4 MB)Author: George H. Self. Example 1: System with a total of 2 devices (1 controller + 1 GPIB communication device) 2 m x 2 devices controller + 2 GPIB communication devices) 2 m x 3 devices.

IEEE is a short-range digital communications 8-bit parallel multi-master interface bus specification developed by Hewlett-Packard as HP-IB (Hewlett-Packard Interface Bus).It subsequently became the subject of several standards, and is generically known as GPIB (General Purpose Interface Bus).

Although the bus was created in the late s to connect together automated test equipment, it. Beginning with version of the GPIB Toolkit, it's no longer necessary to use the GPIB Configurator or another terminal program to switch your Prologix adapter between Device and Controller mode.

Each Toolkit application will configure the Prologix adapter's mode and address settings as necessary. Hints and tips for using GPIB. When using a GPIB system a few items should be observed to make sure the system operates correctly.

Cable routing: When setting up a GPIB system linked by the bus few rules need to be observed. The cables can generally be routed as.

There is always zero or one talker, but there may be many listeners at the same time. Controller address is usually (but need not to be) 0x My simple controller implementation works as follows: Controller takes over bus by assigning REN and IFC (in functions gpib_init() and gpib_controller_assign()).

Then he sends DCL command (using gpib_cmd()). If you are looking for a GPIB Controller that will work nicely with an 8-bit microcontroller, I recommend the NAT or NAT Both are pretty equivalent.

If you have experience with a or that may sway your decision. 0 Kudos Message 3 of 21 (3, Views) Reply. only. Since Prologix GPIB-USB Controller is not the Controller-In-Charge while in this mode, it expects to receive commands from a GPIB controller.

When Device mode is enabled Prologix GPIB-USB controller configures itself as a GPIB Listener. All data received by the controller over the GPIB port is passed along to the USB port without buffering. The system controller has to have a gpib controller card.

These cards can be bought from different vendors such as Hewlett-Packard, National Instruments, Computerboards, Ines and others) The physical connection is a cable with standard connectors on both sides. The standard connector is.

It is equipped with a GPIB bus analyzer function, and data analysis on a line is possible. Since the GPIB controller compatible with uPD developed in CONTEC is used, stable supply is possible over a long period of time.

It can perform setting of each GPIB function by software entirely. This product does not support Windows 64bit version.

In need of info on a GPIB state machine. From surfing the WEB it seems to be available from in their archived standards, and specification, but I'm not an IEEE member. The NEC GPIB controller uPD data book includes state machines, but I can't find that either.

VHDL code would also be helpful. Regards Bob S. RS and RS/RS Serial to GPIB Controller. Adds GPIB Control capability to any computer or PLC with a serial port. Features, Data Sheet and Order >GPIB Controllers.

Ethernet Gateways, PCI GPIB Cards, USB GPIB Controllers, PXI GPIB Cards, ISA bus GPIB Controllers, Serial to GPIB Controllers: Call + to Order. Moved Permanently.

The document has moved here. The maximum bandwidth for GPIB is MB/s or Mb/s for standard IEEE and MB/s or Mb/s for high-speed IEEE This gives Mb/s Ethernet a 7� bandwidth advantage over GPIB. GPIB, however, has a shorter latency than Ethernet. Typical GPIB latency is about �s while Ethernet is in the 1,�s range.

Complete the following steps on the Non-Controller: Use the command ibfind GPIB0 to open a session to the GPIB board. Use the command ibrsc 0 to release system control.

This is where you make it the computer a non-controller. Use the command ibpad 1 to change the primary GPIB address of the Non-Controller from 0 to 1. Page The Gpib-com Controller Function COM sets the THRE bit of the Line Status Register to 0, puts the contents of that register on the GPIB data lines, and begins the source handshake sequence.

When the Listener releases NDAC*, the THRE bit is set back to 1 and the GPIB-COM waits for another byte to be written into the Transmitter Holding. MULTIPLE GPIB CONTROLLERS. spec allows up to eight GPIB controllers to be configured by the same instance of the configuration editor, use the ^F and ^B command on the GPIB controller line of the Interfaces screen to configure each controller.

To include a unit number in a GPIB address for a device, enter the address using the notation unit:address. The Controller function is usually handled by a computer. A computer with the appropriate hardware and software could perform the roles of Talker/Listener and Controller.

THE CONTROLLER-IN-CHARGE AND SYSTEM CONTROLLER Although there can be multiple Controllers on the GPIB, at any time only one Controller is the Controller-In-Charge (CIC.

S:\Hp\EA GPRS Mobile Test Application\ Release\GPIB Syntax Guide\Chapters\ GPIB Syntax for the EA, EA, and EA Diagram Description Statement elements are connected by lines. Each line can be followed in only one direction, as indicated by the arrow at the end of the line.

Prologix GPIB-ETHERNET controller provides a network interface (TCP/IP) to communicate with instruments. Therefore you should use LabVIEW TCP functions or VISA network functions to talk to Prologix controller and attached instruments. Programs, or drivers, that use other interfaces are not compatible.Using only windows headers and ANSI C not likely.

As Adriano points out. The easiest way will be to use the VISA 're a standardized interface to GPIB between different manufacturers (almost) using this library your code and resulting executable won't care whose VISA implementation your using (example caveats linked to below).